Two-night pattern update: 09-14 flagged leak (CPAP hardware) with intact sleep architecture. 09-15 clears the leak concern but surfaces a different CPAP-side signal — flow-limitation load, which is airway-physiology rather than hardware. Sleep quality remains protected in both. If flow-limitation stays this elevated for 2–3 more nights, that would be a signal worth watching (potentially: allergy/congestion, positional airway, or gradual airway sensitivity shift). One night alone is not yet a trend.
| Metric | Value |
|---|---|
| Sleep start | 2026-09-15 23:45:40-05:00 |
| Time in bed | 369.3 min (6h 9.3m) |
| Total sleep | 360.8 min (6h 0.8m) |
| Sleep efficiency | 97.69% |
| Awake time | 8.53 min |
| Core (N1+N2) sleep | 226.3 min / 62.73% |
| Deep (N3) sleep | 45.66 min / 12.66% |
| REM | 88.81 min / 24.62% |
| CPAP usage hours | 6.23 |
| Session count | 1 |
| AHI | 1.93 |
| RDI | 1.93 |
| Obstructive apneas (OA) | 10 |
| Hypopneas (H) | 2 |
| Central apneas (CA) | 0 |
| Unclassified apneas (UA) | 0 |
| RERA | 0 |
| Pressure_Avg | 7.76 |
| Pressure_Min | 4.00 |
| Pressure_Max | 12.18 |
| Pressure_90th | 10.02 |
| Leak_Avg | 0.74 |
| Leak_Max | 14.4 |
| Leak_90th | 2.4 |
| FL_Avg | 0.0186 |
| FL_P95 | 0.12 |
| FL_Max | 0.46 |
| Min_Above_005 | 43.0 |
| Min_Above_010 | 21.2 |
| Min_Above_020 | 6.9 |
| Frac_NonZero (FL samples) | 26.36% |
| Metric | Tonight | 7d avg | 30d avg | Δ vs 7d | Δ vs 30d |
|---|---|---|---|---|---|
| AHI | 1.93 | 2.18 | 2.01 | -11.4% | -4.2% |
| OA count | 10.00 | 10.43 | 9.70 | -4.1% | +3.1% |
| H count | 2.00 | 2.00 | 2.57 | 0.0% | -22.1% |
| CA count | 0.00 | 1.14 | 0.87 | -100.0% | -100.0% |
| RERA count | 0.00 | 0.71 | 0.87 | -100.0% | -100.0% |
| Pressure_Avg | 7.76 | 7.31 | 7.46 | +6.2% | +4.0% |
| Pressure_90 | 10.02 | 9.86 | 10.04 | +1.6% | -0.2% |
| Leak_Avg | 0.74 | 0.61 | 0.81 | +20.7% | -8.3% |
| Leak_Max | 14.40 | 17.49 | 17.84 | -17.7% | -19.3% |
| Leak_90th | 2.40 | 1.54 | 2.20 | +55.6% | +9.1% |
| Usage hours | 6.23 | 6.26 | 6.51 | -0.5% | -4.3% |
| FL_P95 | 0.12 | 0.087 | 0.099 | +37.7% | +21.2% |
| Min_Above_010 | 21.20 | 14.53 | 18.23 | +45.9% | +16.3% |
| Min_Above_020 | 6.90 | 3.99 | 4.24 | +73.1% | +62.7% |
| Awake min | 8.53 | 8.70 | 9.02 | -1.9% | -5.4% |
| TIB min | 369.31 | 366.13 | 384.08 | +0.9% | -3.9% |
| Total sleep min | 360.78 | 357.43 | 375.07 | +0.9% | -3.8% |
| Deep % | 12.66 | 11.60 | 13.06 | +9.2% | -3.1% |
| REM % | 24.62 | 22.15 | 23.51 | +11.2% | +4.7% |
| Core % | 62.73 | 66.26 | 63.42 | -5.3% | -1.1% |
| Metric | Recent 7d | Prior 7d | Δ | Δ % |
|---|---|---|---|---|
| AHI | 2.131 | 2.094 | +0.037 | +1.8% |
| OA | 10.571 | 9.714 | +0.857 | +8.8% |
| CA | 1.143 | 0.429 | +0.714 | +166.7% |
| Pressure_Avg | 7.361 | 7.369 | -0.007 | -0.1% |
| Leak_Avg | 0.559 | 0.936 | -0.377 | -40.3% |
| Leak_90 | 1.371 | 2.743 | -1.371 | -50.0% |
| Deep % (Apple) | 12.40 | 12.80 | -0.40 | -3.1% |
| REM % (Apple) | 23.05 | 21.73 | +1.32 | +6.1% |
| Awake min (Apple) | 8.28 | 10.75 | -2.47 | -23.0% |
| Sleep min (Apple) | 357.93 | 369.67 | -11.73 | -3.2% |
| FL_P95 | 0.091 | 0.093 | -0.002 | -1.5% |
| Min_Above_010 | 15.41 | 15.91 | -0.50 | -3.1% |
| Min_Above_020 | 4.44 | 3.46 | +0.99 | +28.5% |
Recent-week leak averages continue to track well BELOW the prior week (Leak_90 -50%, Leak_Max -21%) — the 09-14 spike was the outlier, not a trend inflection. CA count remains elevated week-over-week (+167%), driven largely by 09-10's 3-CA outlier and 09-14's 2 CAs. Min_Above_020 rose +28.5% week-over-week, and tonight's 6.9 pushes that trend further — worth watching. Sleep architecture week-over-week is stable (Deep -3.1%, REM +6.1%, Awake -23%).
| Date | AHI | OA | CA | PAvg | P90 | LAvg | LMax | L90 | FL_P95 | MinAbv010 | MinAbv020 | Deep% | REM% | Awake |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2026-09-06 | 1.40 | 7 | 1 | 6.72 | 9.44 | 0.27 | 14.4 | 0.0 | 0.08 | 14.4 | 3.8 | 17.64 | 19.40 | 10.04 |
| 2026-09-07 | 1.85 | 9 | 1 | 7.23 | 10.40 | 1.21 | 21.6 | 3.6 | 0.11 | 21.3 | 2.2 | 8.05 | 22.47 | 13.05 |
| 2026-09-08 | 2.25 | 9 | 0 | 7.38 | 9.34 | 1.12 | 18.0 | 3.6 | 0.09 | 15.0 | 3.7 | 7.85 | 19.22 | 11.04 |
| 2026-09-09 | 1.40 | 7 | 1 | 7.68 | 10.52 | 0.63 | 13.2 | 1.2 | 0.11 | 20.5 | 4.8 | 15.10 | 29.01 | 2.51 |
| 2026-09-10 | 2.10 | 10 | 3 | 7.14 | 9.30 | 0.14 | 7.2 | 0.0 | 0.07 | 9.7 | 1.4 | 11.44 | 20.34 | 7.02 |
| 2026-09-11 | 2.53 | 13 | 0 | 6.57 | 9.52 | 0.62 | 24.0 | 0.0 | 0.05 | 8.9 | 2.4 | 11.97 | 21.87 | 10.54 |
| 2026-09-12 | 1.81 | 8 | 1 | 7.17 | 9.92 | 0.45 | 14.4 | 1.2 | 0.08 | 12.7 | 3.9 | 18.06 | 27.63 | 9.53 |
| 2026-09-13 | 2.60 | 14 | 1 | 7.78 | 10.16 | 0.47 | 18.0 | 0.0 | 0.11 | 19.1 | 7.6 | 8.29 | 20.78 | 18.06 |
| 2026-09-14 | 2.55 | 12 | 2 | 7.43 | 10.26 | 0.86 | 27.6 | 4.8 | 0.10 | 15.8 | 4.1 | 14.93 | 21.67 | 3.01 |
| 2026-09-15 | 1.93 | 10 | 0 | 7.76 | 10.02 | 0.74 | 14.4 | 2.4 | 0.12 | 21.2 | 6.9 | 12.66 | 24.62 | 8.53 |
Correlations computed across full available history (2026-06-17 → 2026-09-15).
| Pair | the user r | Interpretation |
|---|---|---|
| AHI vs deep_pct | +0.023 | negligible |
| AHI vs awake_min | +0.059 | negligible |
| OA vs awake_min | +0.093 | negligible |
| CA vs deep_pct | +0.033 | negligible |
| Leak_Avg vs deep_pct | -0.154 | weak negative — higher leak, slightly less deep sleep |
| Leak_90 vs deep_pct | -0.178 | weak negative — same direction |
| Leak_Max vs awake_min | +0.062 | negligible |
| FL_P95 vs awake_min | -0.080 | negligible |
| Min_Above_010 vs deep_pct | +0.020 | negligible |
Bucket comparison (Leak_90 median split, median = 2.4): - Low-leak nights (n=49): mean deep% 15.33, awake 15.25 min - High-leak nights (n=24): mean deep% 12.60, awake 13.09 min - Δ (high – low): deep% -2.73 pp, awake -2.16 min
Tonight (2026-09-15) sits right at the leak median (Leak_90 = 2.4) and had a good sleep-stage outcome: Deep% 12.66 is near the high-leak-bucket mean, and Awake 8.53 min is BELOW both buckets' averages. The much larger deviation tonight is on flow-limitation, and correlations show Min_Above_010 has near-zero predictive power for deep% (r = +0.020), so the elevated FL should NOT be expected to have degraded sleep quality — and indeed did not. The correlation table continues to say leak is the CPAP-side variable most weakly linked to sleep architecture; flow limitation is even weaker on average.
health-report-2026-07-18-to-2026-07-19 2.json duplicate file was again ignored in favor of the primary copy.2026-06-15_2026-07-10.csv roll-up) is present but those early nights have zero-valued pressure and leak channels; these should still be treated as low-confidence for CPAP metrics prior to ~2026-06-22.