Daily Report — 2026-08-02

Sleep & CPAP Report — Night of 2026-08-02

Sources: health-report-2026-08-02-to-2026-08-03.json (Apple Watch sleep stages, exported 08:36 on 08-03) + OSCAR_Greg_by_Day_2026-08-02.csv (ResMed AirSense/AirFlow 11 via OSCAR). Matched by calendar date of sleep-session start (23:02 on 08-02).


⚠️ Flags


1. Summary Table — Night of 2026-08-02

Metric Value
Bedtime (session start) 23:02
Time in bed 5.90 h (354.2 min)
Total sleep duration 5.83 h (349.7 min)
Sleep efficiency (TST/TIB) 98.7% — 3rd-highest in the dataset
Awake time 4.5 min — 2nd-lowest in the dataset (lowest: 4.0 min on 07-29)
Core sleep 3.37 h (202.2 min) — 57.8%
Deep sleep 0.86 h (51.7 min) — 14.8% — near 30-day average (16.5%)
REM sleep 1.60 h (95.8 min) — 27.4% — above 30-day average (24.5%)
CPAP usage 6.02 h
AHI 1.16 — below 30-day average (2.06)
RDI 1.83
OA / H / CA / UA / RERA 3 / 3 / 1 / 0 / 4 — RERA ties all-time high
Pressure avg 7.8 cmH₂O
Pressure 90th %ile 10.3 cmH₂O
Leak avg 0.72 L/min — moderate
Leak 90th %ile 1.2 L/min

2. 8-Night Trend & Leak Context

Date AHI OA RERA Leak avg Leak 90th/95th Deep % Awake (min) Efficiency
07-26 1.24 5 0 0.39 0.0 14.3% 26.6 92.9%
07-27 1.60 8 0 1.19 2.4 18.0% 5.5 98.5%
07-28 2.01 8 2 0.77 2.4 17.8% 11.5 97.2%
07-29 1.62 7 2 1.52 6.0 17.8% 4.0 98.9%
07-30 1.98 13 0 0.08 0.0 11.3% 27.6 93.3%
07-31 1.51 7 0 1.03 3.6 17.9% 24.1 94.9%
08-01 0.58 2 0 0.40 2.4 5.8% 66.7 86.8%
08-02 1.16 3 4 0.72 1.2 14.8% 4.5 98.7%

Leak vs. sleep architecture — 42 matched nights (all available history through 08-02)

Split at leak ≤ 0.30 vs > 0.30 L/min (08-02's leak of 0.72 falls into the higher-leak bucket):

the user r (leak avg vs. deep %): −0.27 (n=42). the user r (leak avg vs. awake min): 0.00. the user r (AHI vs. awake min): 0.00. the user r (AHI vs. deep %): +0.04.

Interpretation: Tonight sits in the higher-leak bucket by a hair (0.72 vs. the 0.30 cutoff) yet posted one of the best awake/efficiency results in the whole dataset — another data point reinforcing that leak level alone doesn't predict a disrupted night. The leak↔deep% relationship remains the one modestly consistent signal (r = −0.27); leak↔awake and AHI↔awake remain essentially flat across 42 nights.


3. Comparison to Trailing Averages

Metric Tonight (08-02) 7-day avg (07-27–08-02) 30-day avg (07-04–08-02)
AHI 1.16 1.49 2.06
Leak avg (L/min) 0.72 0.82 0.59
Pressure avg (cmH₂O) 7.8 6.96 7.95
Usage hours 6.02 7.00 6.68
Deep sleep % 14.8% 14.8% 16.5%
REM sleep % 27.4% 23.2% 24.5%
Awake time (min) 4.5 20.6 17.8

Tonight's usage (6.02 h) is the shortest session of the trailing week — despite that, sleep quality metrics (awake time, efficiency) were among the best in the dataset, underscoring again that shorter, higher-quality sleep opportunities aren't necessarily worse than longer ones (see 08-01's inverse case). AHI and leak are both inside normal range; pressure (7.8) is above the 7-day average but below the 30-day average.

Weekly AHI/Leak trend

Week AHI avg Leak avg n
06-22 to 06-28 2.84 1.98 7
06-29 to 07-05 3.24 1.41 7
07-06 to 07-12 3.00 0.43 7
07-13 to 07-19 2.22 0.42 7
07-20 to 07-26 1.43 0.71 7
07-27 to 08-02 (complete, 7 of 7) 1.49 0.82 7

Trailing-week AHI (1.49) is essentially flat vs. the prior week (1.43) and remains near the lowest levels seen since tracking began. Leak ticked up slightly week over week (0.71 → 0.82) but stays well within the range seen across the dataset.


4. Outlook

The 08-01 anomaly looks like a one-off, not a new trend. Tonight's near-total reversal — from the worst night on record to a top-3 night on efficiency and a top-2 night on awake time — happened within 24 hours and without any corresponding change in CPAP performance (AHI and leak were unremarkable both nights). This is the strongest evidence yet that whatever drove 08-01's disruption (most likely tied to that night's unusually long time-in-bed) was situational rather than a shift in underlying sleep or therapy quality.

RERA count (4) is worth a light watch, not a flag. It ties the dataset's high, but two prior instances of RERA=4 (07-03, 07-15) didn't correspond to notably bad nights either, so this isn't yet a pattern with a downstream effect.

AHI, leak, and pressure remain in a healthy, stable range heading into the next week — no action indicated on the therapy side.


5. Caveats

See all past reports →