Daily Report — 2026-07-26

Sleep & CPAP Report — Night of 2026-07-26

Sources: health-report-2026-07-26-to-2026-07-27.json (Apple Watch sleep stages, exported 05:48 on 07-27) + OSCAR_Greg_by_Day_2026-07-26.csv (ResMed AirSense/AirFlow 11 via OSCAR). Matched by calendar date of sleep-session start (22:57 on 07-26).


⚠️ Flags


1. Summary Table — Night of 2026-07-26

Metric Value
Bedtime (session start) 22:57
Time in bed 6.28 h (376.8 min)
Total sleep duration 5.84 h (350.2 min)
Sleep efficiency (TST/TIB) 92.9% (flat vs. 07-25, still below 7-day avg)
Awake time 26.6 min ↓ from 30.6 but 5th-highest in dataset
Core sleep 3.54 h (212.3 min) — 60.6%
Deep sleep 0.84 h (50.2 min) — 14.3% ↑ from 9.9% but still below trailing avg
REM sleep 1.46 h (87.8 min) — 25.1%
CPAP usage 6.47 h
AHI 1.24 ↓ (back within 07-20–23 baseline)
RDI 1.24
OA / H / CA / UA / RERA 5 / 3 / 0 / 0 / 0
Pressure avg 7.59 cmH₂O
Pressure 90th %ile 10.02 cmH₂O
Leak avg 0.39 L/min ↓↓ (resolved, down 77% from 1.69)
Leak max 14.4 L/min
Leak 90th %ile 0.0 L/min ↓ (down from 7.2)

2. 8-Night Trend & Leak Context

Date AHI OA RERA Leak avg Leak 90th Deep % Awake (min) Efficiency
07-19 1.29 6 1 0.92 0.0 10.1% 14.0 96.2%
07-20 0.94 2 0 0.03 0.0 8.3% 21.1 94.4%
07-21 0.88 4 1 0.85 1.2 28.4% 27.1 93.3%
07-22 1.59 7 1 1.08 2.4 12.0% 10.0 97.5%
07-23 1.29 7 0 0.48 2.4 25.5% 13.0 96.8%
07-24 2.34 15 0 0.48 0.0 16.7% 24.6 93.9%
07-25 1.72 10 0 1.69 7.2 9.9% 30.6 92.5%
07-26 1.24 5 0 0.39 0.0 14.3% 26.6 92.9%

Leak vs. sleep architecture — 35 matched nights (all available history)

Split at leak ≤ 0.30 vs. > 0.30 L/min (07-26's leak of 0.39 falls just above the threshold, into the higher-leak bucket, despite being a comparatively mild reading):

the user r (leak avg vs. deep %): −0.298 (n=35, was −0.30). the user r (leak avg vs. awake min): +0.096 (was +0.12). the user r (AHI vs. awake min): +0.138 (was +0.18). the user r (AHI vs. deep %): +0.056 (was +0.05).

Interpretation: The leak→deep-sleep relationship held steady. But both awake-time correlations weakened with tonight's data point added, because 07-26 combines low leak (0.39) and low AHI (1.24) with high awake time (26.6 min, 5th-highest on record) — a genuine counterexample to the "leak/AHI drives awake time" story that the prior two reports had been building. All |r| values remain in the weak 0.05–0.30 range; treat directional tendencies, not tonight's outcome, as the reliable signal.


3. Comparison to Trailing Averages

Metric Tonight (07-26) 7-day avg (07-20–07-26) Prior 7-day avg (07-13–07-19) 30-day avg (06-27–07-26)
AHI 1.24 1.43 2.22 2.45
Leak avg (L/min) 0.39 0.71 0.42 0.82
Pressure avg (cmH₂O) 7.59 7.46 8.77 8.41
Usage hours 6.47 6.77 6.32 6.58
Deep sleep % 14.3% 16.4% 14.7% 16.6%
REM sleep % 25.1% 26.4% 21.5% 24.2%
Awake time (min) 26.6 21.9 15.8 16.9

AHI, leak, and pressure are all now at or below their trailing 7-day and 30-day averages — the CPAP-side picture looks clean. Deep sleep (14.3%) sits about 2 points below both trailing windows, and awake time (26.6 min) is roughly 1.2x the 7-day average and 1.6x the 30-day average — the sleep-architecture side is the lagging piece tonight, not the therapy metrics.

Weekly AHI/Leak trend

Week AHI avg Leak avg n
06-22 to 06-28 2.84 1.98 7
06-29 to 07-05 3.24 1.41 7
07-06 to 07-12 3.00 0.43 7
07-13 to 07-19 2.22 0.42 7
07-19 to 07-25 (prior trailing 7d) 1.44 0.79 7
07-20 to 07-26 (current trailing 7d) 1.43 0.71 7

The multi-week AHI downtrend holds essentially flat at its recent low (1.44 → 1.43). Trailing leak eased back down (0.79 → 0.71) as the 07-25 spike aged out of most of the window's influence — it's still the single highest value inside the current 7-day window, but the six other nights (0.03–1.24) keep the average moderate.


4. Outlook

CPAP-side metrics (AHI, OA, leak, pressure): all clear. No action items — this looks like a fully resolved single-night event on 07-25, exactly as anticipated in the prior report.

Primary open question: why didn't awake time and efficiency follow leak/AHI back down? Two consecutive nights (07-25, 07-26) now rank in the dataset's worst decile for both awake time and efficiency, despite CPAP metrics being unremarkable on the second of those nights. Possible explanations worth considering over the next few nights: a one-night lag/carryover effect from a disrupted prior night, an unmeasured factor (caffeine, alcohol, stress, room temperature, etc.) coinciding with both nights, or simply two independent rough nights. If 07-27 also shows elevated awake time or low efficiency with otherwise-normal CPAP metrics, that would point away from CPAP therapy as the driver and toward something else in the routine around 07-25–07-26.

Deep sleep: Trending back toward baseline (9.9% → 14.3%) but not there yet; watch for continued recovery toward the ~16–17% recent norm.


5. Caveats