Daily Report — 2026-07-22

Sleep & CPAP Report — Night of 2026-07-22

Sources: health-report-2026-07-22-to-2026-07-23.json (Apple Watch sleep stages, exported 08:10 on 07-23) + OSCAR_Greg_by_Day_2026-07-22.csv (ResMed AirSense/AirFlow 11 via OSCAR). Matched by calendar date of sleep-session start (22:27 on 07-22).


⚠️ Flags


1. Summary Table — Night of 2026-07-22

Metric Value
Bedtime (session start) 22:27
Time in bed 6.81 h (408.4 min)
Total sleep duration 6.64 h (398.4 min)
Sleep efficiency (TST/TIB) 97.6%
Awake time 10.0 min — lowest in 7-night dataset
Core sleep 3.75 h (224.8 min) — 56.4%
Deep sleep 0.79 h (47.7 min) — 12.0%
REM sleep 2.10 h (125.9 min) — 31.6% — highest in dataset
CPAP usage 6.9 h
AHI 1.59
RDI 1.74
OA / H / CA / UA / RERA 7 / 4 / 0 / 0 / 1
Pressure avg 7.60 cmH₂O
Pressure 90th %ile 10.48 cmH₂O
Pressure max 12.0 cmH₂O
Leak avg 1.08 L/min ↑ (2nd consecutive elevated night)
Leak max 31.2 L/min
Leak 90th %ile 2.4 L/min (doubled from 1.2 prior night)

2. 7-Night Architecture Trend & Leak Context

Date AHI RERA Leak avg Leak 90th Deep % Deep (min) REM % Awake (min) Efficiency
07-16 1.50 3 0.13 0 16.6% ~70 20.6% 12.5 96.3%
07-17 2.78 0 0.27 1.2 16.4% ~69 30.0% 7.0 98.2%
07-18 2.35 0 0.54 0 14.7% ~63 23.1% 36.6 90.3%
07-19 1.29 1 0.92 0 10.1% ~43 17.0% 14.0 96.2%
07-20 0.94 0 0.03 0 8.3% 29.6 21.0% 21.1 94.4%
07-21 0.88 1 0.85 1.2 28.4% 106.9 24.8% 27.1 93.3%
07-22 1.59 1 1.08 2.4 12.0% 47.7 31.6% 10.0 97.6%

Leak escalation pattern (07-21 and 07-22)

The leak profile has shifted across two nights: - Leak avg: 0.85 → 1.08 (+0.23 L/min) - Leak 90th: 1.2 → 2.4 L/min (doubled) - Leak max: 22.8 → 31.2 L/min

The rising 90th-percentile is the more informative signal — it indicates the leak is sustained over more of the night, not just a brief positional spike. Prior high-leak episodes (07-18, 07-19) had 90th percentile of 0 (i.e., no sustained component); the last two nights both show real 90th-pct values.

Leak vs. sleep architecture — 7 matched nights (07-16 to 07-22)

Split at leak ≤ 0.30 vs. > 0.30 L/min:

the user r (leak avg vs. deep%): +0.19 — directionally flat; the dataset remains too small for meaningful inference. the user r (leak avg vs. awake min): +0.02 — effectively zero across 7 nights. The 07-21 recovery night and tonight's excellent sleep continuity have decoupled leak from awake time in this sample.

Working interpretation: The mask seal issue is a hardware problem worth fixing on its own terms, independent of sleep quality impact. The fact that tonight showed excellent sleep (10 min awake, 31.6% REM) despite 1.08 avg leak may indicate tolerance, positional luck, or that the leaks are occurring during REM-dense periods where the machine compensates. But tolerance to moderate leak doesn't rule out worsening: if avg leak reaches 2+ L/min, therapy efficacy risk rises.


3. Comparison to Trailing Averages

Metric Tonight (07-22) 7-day avg (07-16–07-22) Prior 7-day avg (07-15–07-21) 30-day avg (06-23–07-22)
AHI 1.59 1.62 1.82 2.70
RDI 1.74 1.76 2.02 —
RERA 1 0.86 1.29 ~1.14
Pressure avg (cmH₂O) 7.60 8.10 8.27 8.49
Leak avg (L/min) 1.08 0.55 0.43 1.05†
Usage hours 6.9 6.45 6.42 6.53
Deep sleep % 12.0% 15.2%‡ 15.8%‡ —
REM sleep % 31.6% 24.0%‡ 22.8%‡ —
Awake time (min) 10.0 18.3‡ 19.7‡ —

†30-day leak avg includes Jul 01 (6.22 L/min outlier from mask failure); without that night: (31.63 - 6.22) / 29 = 0.88 L/min.
‡Sleep-stage averages cover only the 7 matched nights (Jul 16–22) with both Apple Watch and CPAP data.

Weekly AHI/RERA/Leak trend

Week AHI avg RERA avg Leak avg n
06-22 to 06-28 2.84 ~0.86 1.98 7
06-29 to 07-05 3.24 ~1.29 1.41 7
07-06 to 07-12 3.00 ~1.14 0.43 7
07-13 to 07-19 2.22 2.00 0.42 7
07-16 to 07-22 (trailing 7d) 1.62 0.86 0.55 7

AHI continues declining week-over-week (1.62 is a new trailing-7-day low). RERA has also dropped back from the 2.00 spike in the 07-13–19 window. Leak avg has ticked up slightly due to the last two nights but is still well below the mid-June 1.98 level. Pressure average continues to drift lower (8.49 → 8.27 → 8.10 → 7.60 tonight), consistent with the machine dialing back as respiratory load decreases — a positive efficiency signal.


4. Outlook

The primary watch item remains mask seal. Two consecutive nights of rising leak (avg 0.85 → 1.08, 90th pct 1.2 → 2.4) with an increasing max is a clear pattern. If tomorrow (07-23) shows leak avg ≥ 0.8 or 90th pct ≥ 2.0, a mask cushion inspection is warranted — look for wear, deformation, or pillow compression that would shift fit during the night. The otherwise strong sleep metrics tonight (97.6% efficiency, 10 min awake, 31.6% REM) are genuinely good and suggest the leak hasn't yet impacted sleep architecture, but the trend direction is worth addressing before it does.

Deep sleep at 12% is a normal baseline value after the 07-21 recovery spike; expect this to stabilize in the 12–18% range over the coming week. REM at 31.6% is the highest recorded value and is a positive signal — no action needed.


5. Caveats